Description
Technical Datasheet
| PRODUCT MODEL | ZX-3M-0816 | ZX-3M-1020 |
| PV INPUT | ||
| Max PV array power | 16000 Wp | 20000 Wp |
| Max input voltage | 550 V | |
| MPP voltage range / rated input voltage | 40-530 V / 380 V | |
| Min input voltage / start voltage | 40 V / 50 V | |
| No. of independent MPPT trackers / strings per MPPT input | 3 / 1 | |
| Max input current / Max power per MPPT tracker | 20 A / 10000 W | 20 A / 10000 W |
| Max short-circuit current per MPPT tracker | 25 A | |
| BATTERY INPUT | ||
| Battery voltage range | 40 V to 60 V | |
| Max charge / discharge power | 8000 W | 10000 W |
| Max charge current / Max discharge current | 190 A | 210 A |
| Battery type | LiFePO4 / Lead-acid | |
| AC OUTPUT | ||
| AC voltage range / Nominal AC voltage | 154 V to 276 V / 220, 230, 240 L/N | |
| Rated AC grid frequency | 50 Hz / 60 Hz | |
| AC grid frequency range | 45-55 Hz / 55-65 Hz | |
| Rated apparent power | 8000 VA | 10000 VA |
| Max apparent power | 8800 VA | 11000 VA |
| Rated grid output current (@230 V) | 34.8 A | 43.5 A |
| Max grid output current (@230 V) | 38.3 A | 47.8 A |
| Harmonic distortion (THD) at rated output | < 3% (of nominal power) | |
| Power factor at rated power / adjustable range | 1 / 0.8 leading to 0.8 lagging | |
| AC INPUT | ||
| Nominal AC voltage | 220, 230, 240 V, L/N | |
| Rated grid frequency | 50 Hz / 60 Hz | |
| Max input power from grid | 16000 W | 18000 W |
| Max input current from grid | 69.6 A | 78.3 A |
| EPS OUTPUT | ||
| Nominal AC voltage | 220, 230, 240 V, L/N | |
| Nominal output frequency | 50 Hz / 60 Hz | |
| Rated apparent power | 8000 VA | 10000 VA |
| Peak output apparent power (off-grid up to 10s) | 16000 VA | 20000 VA |
| Rated current (@230 V) | 34.8 A | 43.5 A |
| Max current (@230 V, continuous on-grid / off-grid) | 38.3 A | 47.8 A |
| Max switch time | < 10 ms | |
| Output THDv (@ linear load) | 2% | |
| GENERATOR SIDE | ||
| Max input apparent power | 8000 VA | 10000 VA |
| Max charge / discharge power | 8000 VA | 10000 VA |
| Max input current | 36.4 A | 45.5 A |
| Rated AC voltage | 220, 230, 240 V, L/N | |
| Rated AC frequency | 50 Hz / 60 Hz | |
| EFFICIENCY | ||
| MPPT efficiency | 99.9% | |
| European efficiency / Max efficiency | 97% / 97.6% | |
| SAFETY PROTECTION | ||
| Surge protection | ● / Type II | |
| Insulation resistance detection | ● | |
| PV string input reverse polarity protection | ● | |
| Ground fault monitoring | ● | |
| Residual current monitoring unit | ● | |
| AC short circuit protection | ● | |
| Anti-islanding protection | ● | |
| GENERAL DATA | ||
| Dimensions (W / H / D) | 484 / 676 / 230 mm | |
| Weight | 34.5 kg | |
| Operating temperature range | -25°C ~ +60°C | |
| Cooling concept | Smart cooling | |
| Degree of protection | IP66 | |
| Max relative humidity | 100% | |
| Max operating altitude | 3000 m | |
| INTERFACE | ||
| User interface | LED & App | |
| BMS interface | CAN | |
| Communication interfaces |
Dongle WiFi (2.4 GHz) / LAN (100 Mbps) Inverter: RS485 (Modbus RTU), LAN (100 Mbps, Modbus TCP only) |
|
| Digital output (dry contact) / No. of outputs | 0 / 2 | |
| Digital input (dry contact) / No. of inputs | 0 / 6 | |
| Integrated power control / export power control | ● / ● | |